RT Journal Article SR Electronic T1 Novel approach to diagnosis of His bundle capture using individualized left ventricular lateral wall activation time as reference JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2021.05.28.21257962 DO 10.1101/2021.05.28.21257962 A1 Marek Jastrzębski A1 Paweł Moskal A1 Piotr Kukla A1 Agnieszka Bednarek A1 Grzegorz Kiełbasa A1 Marek Rajzer A1 Karol Curila A1 Pugazhendhi Vijayaraman YR 2021 UL http://medrxiv.org/content/early/2021/05/28/2021.05.28.21257962.abstract AB Aims During non-selective His bundle (HB) pacing, it is clinically important to confirm His bundle capture vs. right ventricular septal (RVS) capture. The present study aimed to validate the hypothesis that during HB capture left ventricular lateral wall activation time, approximated by the V6 R-wave peak time (V6RWPT), will not be longer than the corresponding activation time during native conduction.Methods Consecutive patients with permanent HB pacing were recruited; cases with abnormal His-ventricle interval or left bundle branch block were excluded. Two corresponding intervals were compared: stimulus-V6RWPT and native HBpotential-V6RWPT. Difference between these two intervals (delta V6RWPT), diagnostic of lack of HB capture, was identified using receiver operating characteristic (ROC) curve analysis.Results A total of 723 ECGs (219 with native rhythm, 172 with selective HB, 215 with non-selective HB, and 117 with RVS capture) were obtained from 219 patients. The native HB-V6RWPT, non-selective-, and selective-HB paced V6RWPT were nearly equal, while RVS V6RWPT was 32.0 (±9.5) ms longer. The ROC curve analysis indicated delta V6RWPT > 12 ms as diagnostic of lack of HB capture (specificity of 99.1% and sensitivity of 100%). A blinded observer correctly diagnosed 96.7% (321/332) of ECGs using this criterion.Conclusion We validated a novel criterion for HB capture that is based on the physiological left ventricular activation time as an individualized reference. HB capture can be diagnosed when paced V6RWPT does not exceed the value obtained during native conduction by more than 12 ms, while longer paced V6RWPT indicates RVS capture.Competing Interest StatementThe authors have declared no competing interest.Funding Statementno fundingAuthor DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:Bioethical Committe of Jagiellonian University Medical CollegeAll necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesData avilable upon reasonable request