RT Journal Article SR Electronic T1 Regional ventilation characteristics during non-invasive respiratory support in preterm infants JF medRxiv FD Cold Spring Harbor Laboratory Press SP 2020.08.04.20168575 DO 10.1101/2020.08.04.20168575 A1 Thomson, J A1 Rueegger, CM A1 Perkins, EJ A1 Pereira-Fantini, PM A1 Farrell, O A1 Owen, LS A1 Tingay, DG YR 2020 UL http://medrxiv.org/content/early/2020/10/20/2020.08.04.20168575.abstract AB Objective To determine the regional ventilation characteristics during non-invasive ventilation in stable preterm infants. The secondary aims were to explore the relationship between indicators of ventilation homogeneity and other clinical measures of respiratory status.Design Prospective observational study.Setting Two tertiary neonatal intensive care units.Patients Forty stable preterm infants born <30 weeks gestation receiving either continuous positive applied pressure (n=32) or nasal high-flow cannualae (n=8) at least 24 hours after extubation at time of study.Interventions Continuous electrical impedance tomography imaging of regional ventilation during 60-minutes of quiet breathing on clinician-determined non-invasive settings.Main outcome measures Gravity-dependent and right-left centre of ventilation (CoV), percentage of whole lung tidal volume by lung region, and percentage of lung unventilated were determined for 120 artefact-free breaths/infant (4770 breaths included). Oxygen saturation, heart and respiratory rates were also measured.Results Ventilation was greater in the right lung (mean (SD) 69.1 (14.9)%) total tidal volume and the gravity-nondependent lung; ideal-actual CoV 1.4 (4.5)%. The central third of the lung received the most tidal volume, followed by the non-dependent and dependent regions (p<0.0001 repeated measure ANOVA). Ventilation inhomogeneity was associated with worse SpO2/FiO2, (p=0.031, r2 0.12; linear regression). In those infants that later developed bronchopulmonary dysplasia (n=25) SpO2/FiO2 was worse and non-dependent ventilation inhomogeneity greater than in those that did not (both p<0.05; t test Welch correction).Conclusions There is high breath-by-breath variability in regional ventilation patterns during NIV in preterm infants. Ventilation favoured the gravity-nondependent lung, with ventilation inhomogeneity associated with worse oxygenation.Competing Interest StatementThe authors have declared no competing interest.Clinical TrialAustralian and New Zealand Clinical Trials Registry (ACTRN12616001516471)Funding StatementThis study is supported by the Victorian Government Operational Infrastructure Support Program (Melbourne, Australia). DGT is supported by a National Health and Medical Research Council Clinical Career Development Fellowship (Grant ID 1053889). CMR is supported by a Swiss National Science Foundation Early Postdoctoral Mobility fellowship (P2ZHP3_161749) and the Milupa Fellowship Award of the Swiss Society of Neonatology. SenTec AG (Landquart, Switzerland) manufactured custom-built EIT belts for infants. All EIT hardware was purchased by MCRI without any restrictions.Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.YesThe details of the IRB/oversight body that provided approval or exemption for the research described are given below:This study was approved by the Royal Childrens Hospital Human Research Ethics Committee (HREC 36159A) and the Royal Womens Hospital Human Research Ethics Committee (HREC 16-33), in accordance with the National Health and Medical Research Council Statement of Ethical Conduct in Human Research (2007).All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.YesI understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).YesI have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.YesDeidentified individual participant data, study protocols and statistical analysis codes are available from three months to 23 years following article publication to researchers who provide a methodologically sound proposal, with approval by an independent review committee (learned intermediary). Proposals should be directed to david.tingay{at}mcri.edu.au to gain access. Data requestors will need to sign a data access or material transfer agreement approved by MCRI.