ABSTRACT
Background People with lower-limb amputations lack sensory inputs from their missing limb, which increases their risk of falling. We recently demonstrated that spinal cord stimulation (SCS) can restore sensation in the missing lower limb. Previous studies have shown that SCS can affect motor control by exciting spinal reflex pathways after stroke or spinal cord injury. The effects of SCS on spinal reflex activation have not been studied in people with lower-limb amputation. Furthermore, it is unknown if SCS-evoked spinal reflex activation would perturb walking. Therefore, the goal of this study was to characterize SCS-evoked spinal reflexes in people with lower-limb amputation and quantify effects on gait parameters, including step cycle duration and limb alternation symmetry.
Methods We implanted percutaneous SCS electrodes over the lumbosacral enlargement in 3 people with trans-tibial amputation (2 diabetic neuropathy; 1 traumatic) for 28 or 84 days. SCS was delivered to restore sensation in the missing limb during walking based on signals from a pressure-sensing insole in the shoe under the prosthesis. We used electromyography (EMG) to record posterior root-muscle (PRM) reflexes in the residual limb while participants were seated, standing, or walking. We characterized rate-dependent depression and recruitment properties of the PRM reflexes. We used pressure data from instrumented insoles to measure the step cycle duration and limb alternation symmetry with and without SCS.
Results SCS evoked PRM reflexes in the residual limb muscles in all participants, which was confirmed by the presence of rate-dependent depression at stimulation frequencies ≥2Hz. Overall, there was broad activation of residual limb muscles with SCS that varied with the position of the stimulating electrode relative to the lumbar spinal cord. PRM reflexes were also activated during walking, as confirmed by the presence of rate-dependent depression. However, SCS-evoked PRM reflexes did not disrupt gait, with similar step cycle duration or limb alternation symmetry with and without SCS.
Conclusions Restoring sensation in the missing limb using SCS excites spinal reflexes according to the expected rostral-caudal myotomes but does not disrupt the step cycle duration or limb alternation symmetry in people with trans-tibial amputation.
Competing Interest Statement
MC and DJW are founders and shareholders of Reach Neuro, Inc.; DJW is a consultant and shareholder of Neuronoff, Inc. and Panther Life Sciences, Inc.; DJW is a shareholder and scientific board member for NeuroOne Medical, Inc.; DJW is a co-founder and shareholder of Bionic Power Inc. BB is the inventor of several patents involving technologies for the electrical stimulation of the spinal cord. The other authors declare no conflicts of interests in relation to this work.
Clinical Trial
NCT03027947 and NCT04547582
Funding Statement
This study was funded by the National Institutes of Health (NINDS Award number UH3NS100541 and NICHD Award Number F30HD0987984).
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
All procedures were approved by the Institutional Review Board at the University of Pittsburgh and conformed to the Declaration of Helsinki. This study was registered under clinical trials NCT03027947 and NCT04547582.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
LIST OF ABBREVIATIONS
- SCS
- spinal cord stimulation
- PRM
- posterior root-muscle
- EMG
- electromyography
- RF
- rectus femoris
- VM
- vastus medialis
- VL
- vastus lateralis
- BF
- biceps femoris
- ST
- semitendinosus
- TA
- tibialis anterior
- LG
- lateral gastrocnemius
- MG
- medial gastrocnemius
- SO
- soleus
- SD
- standard deviation
- RDD
- rate-dependent depression
- tSCS
- transcutaneous spinal cord stimulation
- CSF
- cerebrospinal fluid
The Chan Zuckerberg Initiative, Cold Spring Harbor Laboratory, the Sergey Brin Family Foundation, California Institute of Technology, Centre National de la Recherche Scientifique, Fred Hutchinson Cancer Center, Imperial College London, Massachusetts Institute of Technology, Stanford University, University of Washington, and Vrije Universiteit Amsterdam.