Abstract
Appropriate collection of respiratory samples is essential for accurate diagnostic testing of respiratory pathogens such as, SARS-CoV-2. Early in the pandemic, there was a shortage of nasopharyngeal (NP) swabs and difficulty in sampling suspected cases. Therefore, we developed a 3D printed nasal swab for anterior nares, paired with in-house viral transport medium (VTM). The utility of this 3D swab kit was investigated in comparison with the standard NP commercial swab and VTM, in 200 individuals between August and September 2021. Subjects were those presenting for diagnostic testing for SARS-CoV-2 using the RT-PCR (cobas Roche assay) assay. NP samples were taken from each subject using the standard NP and 3D swabs followed by RT-PCR on paired specimens. CT values for amplification of gene targets were evaluated to determine assay parameters based on viral load cut offs of ≤ CT 35 or, ≤ CT 37. For high to medium viral loads, 3D swab based PCR testing had a sensitivity of 93%, specificity of 99%, positive predictive value (PPV) of 98.5% and negative predictive value (NPV) of 96.2% respectively. For low viral loads, 3D swab testing had a sensitivity of 88%, specificity of 99%, with a PPV of 98.5% and NPV of 93.2%.%. 3D swab sampling of anterior nares was comparable with NP sampling using standard swabs for SARS-CoV-2 specimens with a medium to high viral load. Therefore, 3D swab based sampling is a reliable and convenient local solution for collecting respiratory samples for SARS-CoV-2 diagnostic testing.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The study was funded by the Aga Khan Development Network
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
Ethical Review Committee, Aga Khan University, Pakistan
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Data Availability
All data produced in the present work are contained in the manuscript