Abstract
Objectives This study was undertaken to assess the amount of dental aerosol created in a primary care dental surgery.
Methods Two particle meters were placed a set distances round a volunteer patient whilst undergoing simulated dental treatment using a high speed dental handpiece, and 3-in-1 air/water syringe, moisture control was managed with high volume suction and a saliva ejector. Measurement were taken every thirty seconds with the surgery environment set a neutral ventilation and with the windows open plus fan assistance.
Results From the cessation of aerosol generation it took between 6 and 19 minutes for the surgery to return to baseline. The ventilated surgery had faster aerosol dispersal, returning to background levels within 5 minutes.
Conclusion It is concluded for the surgery under investigation the dental aerosol had dissipated after 30 minutes using HVS and optimal surgery.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
No funding was received for this article
Author Declarations
I confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
No IRB/ethics committee approvals were necessary
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Paper in collection COVID-19 SARS-CoV-2 preprints from medRxiv and bioRxiv
The Chan Zuckerberg Initiative, Cold Spring Harbor Laboratory, the Sergey Brin Family Foundation, California Institute of Technology, Centre National de la Recherche Scientifique, Fred Hutchinson Cancer Center, Imperial College London, Massachusetts Institute of Technology, Stanford University, University of Washington, and Vrije Universiteit Amsterdam.