Abstract
In the case of a public health emergency such as the COVID-19 pandemic, access to large quantities of appropriate personal protection equipment (PPE) has presented a significant problem. A shortage of face masks and respirators has been widely reported across the world. A concerted effort to manufacture high volumes has not unsurprisingly put pressure on the supply chain and the important certification processes. PPE procured or donated as uncertified stock requires rigorous, expedient and scientifically informed evidence before decisions can be made regarding suitable deployment, expensive certification, return or possible destruction of stock. This paper reports a series of experiments devised in reaction to this situation. In this study, an experimental methodology for the assessment of the filtration performance of samples of real-world, uncertified, fluid resistant surgical masks (FRSM type IIR) was evaluated in the resource limited (lockdown) environment of the COVID-19 pandemic. A steady-state flow rig was adapted to incorporate a bespoke filter flow chamber for mounting face masks in order to evaluate the resistance to air flow as an indicator of mask inhalation performance. Pure air was drawn through a specified control surface area at known flow rate conditions; the resistance to the air flow through the masks was measured as the resulting pressure drop. Over 60 tests were performed from 4 different, randomly sampled batches and compared to a control sample of EN Type IIR certified FRSM masks. Steady-state volumetric airflow rates of 30 and 95 lmin−1 were chosen to represent deep breathing and vigorous exercise conditions respectively. The results showed that the sample masks produced a pressure drop of between 26% to 58% compared to the control batch at the lower flow rate and 22% to 55% at the higher rate. The results for each sample were consistent across both flow rates. Within the group of masks tested, two sets (between 48% and 58% of the reference set) showed the potential to be professionally assessed for appropriate deployment in a suitable setting. Although the absolute values of pressure drop measured by this method are unlikely to correlate with other testing approaches, the observed, indicative trends and relative performance of the masks is key to this approach. Critically, this method does not replace certification but it has enabled a public body to quickly make decisions; certify, re-assign, refund, thus saving time and resources. The total time spent conducting the tests was less than 8 hours and the low cost method proposed can be repurposed for low resource regions.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
No external funding was received
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All the data have been reported