Abstract
The recent outbreak of the newly emerged novel coronavirus (SARS-CoV-2) presents a big challenge for public health laboratories as virus isolates are not available while there is an increasing evidence that the epidemic is more widespread than initially thought, as well as spreading internationally across borders through travellers does already happen warranting a methodology for the rapid detection of the infection to control SARS-CoV-2. Aim: We intended to develop and deploy a robust and rapid diagnostic methodology using LAMP assay for use in point of care settings to detect SARS-COV-2 infection. Methodology: In the present study, we have developed a validated rapid diagnostic procedure to detect SARS-CoV-2 using LAMP assay, its design relying on isothermal amplification of the nucleic acids of the SARS-CoV-2. Results: The LAMP assay developed detects SARS-CoV-2 infection rapidly with high sensitivity and reliability. The data generated by LAMP assay were comparable and at par with the data generated by real-time PCR method. Conclusion: The present study demonstrates that the LAMP assay developed was a rapid, reliable, sensitive and cost effective method to detect SARS-CoV-2 infection in a point of care as well as in laboratory settings.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
The present study was not funded by any funding agency or organization.
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data reported in the manuscript are generated by original research carried out at AURA BIOTECHNOLOGIES PRIVATE LIMITED, CHENNAI, INDIA and the data are available.