Abstract
BACKGROUND In December 2019, a novel coronavirus (SARS-CoV-2)–infected pneumonia (COVID-19) occurred in Wuhan, China. Travel-associated cases have also been reported in other countries. The number of cases has increased rapidly but laboratory diagnosis is limited.
METHODS We collect two groups of cases diagnosed with COVID-19 for experiments. One group collected 63 samples for Enzyme-linked immunosorbent assay (ELISA) IgG and IgM antibodies. The other group collected 91 plasma samples for colloidal gold-immunochromatographic assay (GICA).
RESULTS The sensitivity of the combined ELISA IgM and ELISA IgG detection was 55/63 ( 87.3%), The sensitivity of the combined GICA IgM and GICA IgG detection was 75/91 ( 82.4%), Both methods are negative for healthy controls, specificity of 100%. There is no significant difference between the sensitivity of between ELISA and GICA (IgM+ IgG).
CONCLUSIONS ELISA and GICA for specific IgM and IgG antibodies are conventional serological assays, they are simple, fast, and safe, the results can be used for clinical reference, and the huge clinical diagnosis and treatment pressure can be greatly relieved.
Competing Interest Statement
The authors have declared no competing interest.
Funding Statement
This work was supported by the Zhongnan Hospital of Wuhan University Science, Technology and Innovation Seed Fund under Grant znpy2017022.
Author Declarations
All relevant ethical guidelines have been followed; any necessary IRB and/or ethics committee approvals have been obtained and details of the IRB/oversight body are included in the manuscript.
Yes
All necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines and uploaded the relevant EQUATOR Network research reporting checklist(s) and other pertinent material as supplementary files, if applicable.
Yes
Data Availability
All data generated or analyzed during this study are included in this published article and its supplementary information files.