Abstract
Objectives To compare clinical outcomes after percutaneous coronary intervention (PCI) using titanium-nitride-oxide coated stents (TiNOS) versus drug-eluting stents (DES) in coronary artery disease (CAD) including acute coronary syndrome (ACS).
Design Prospective systematic literature (SLR) conducted according to PRISMA. Medline, Embase, Cochrane, Web of Science were searched in March 2018 and updated.
Setting Interventional cardiology.
Participants Patients with CAD, including ACS, requiring PCI.
Interventions All prospective randomized controlled trials (RCTs) that compared clinical outcomes after PCI with DES versus TiNOS.
Outcome measures The pooled risk ratios (RR), TiNOS over DES, with 95% confidence intervals (CI) are computed for device-oriented Major Adverse Cardiac Events (MACE), non-fatal myocardial infarction (MI), cardiac death (CD), clinically driven target lesion revascularization (TLR), probable or definite stent thrombosis (ST), total mortality, at one to five years after PCI. Pooled RRs are stratified according to baseline ACS versus other CAD. Sensitivity analysis (SA) and certainty of the evidence are rated per GRADE.
Results Five RCTs are eligible with 1,855 patients with TiNOS versus 1,363 with DES at 1-year follow-up and 783 versus 771 at 5-year. Three RCTs included patients with ACS only. One-year RRs in ACS are: MACE 0.93 [0.72, 1.20], MI 0.48 [0.31, 0.73], CD 0.66 [0.33, 1.31], TLR 1.55 [1.10, 2.19] and ST 0.35 [0.20, 0.64]. One-year MACE, MI, and ST are robust to SA. The certainty of the evidence is high in MACE, moderate in MI, and low or very low in the other endpoints. There are too few observations to conclude about other CAD and 5-year outcomes. However, 5-year interim results are consistent with 1-year conclusions.
Conclusions A similar risk of MACE is found in TiNOS and DES, with potentially fewer MI and ST but more TLR in TiNOS. TiNOS are safe and effective in ACS at 1-year follow-up.
Registration PROSPERO CRD42018090622
Strengths and limitations of this study
- Strengths:
The level of certainty of the evidence is high for the primary endpoint at one-year follow-up in patients treated for acute coronary syndrome.
The primary endpoint and critical secondary endpoints are robust to sensitivity analysis.
- Limitations:
Outcomes in patients treated for chronic coronary artery disease cannot be analyzed.
The level of certainty of the evidence of secondary endpoints is moderate or low.
Analysis of five-year outcomes is still at an interim stage.
Objectives
Percutaneous coronary interventions (PCI) with drug-eluting stents (DES) is the standard of care in Coronary Artery Disease (CAD), including Acute Coronary Syndrome (ACS).1-6 mTOR inhibitors such as everolimus and paclitaxel have been the main drug types used on stents to inhibit post-stenting restenosis.7-9 Their side effect is the increased risk of stent thrombosis (ST), requiring prolonged Dual AntiPlatelet Therapy (DAPT) with its own risk of complications.10,11 Titanium-nitride-oxide coated coronary stents (TiNOS), also designated “bioactive stents” (BAS) have a pharmacologically inactive, non-absorbable coating. Preclinical data has shown less neointimal hyperplasia with TiNOS than with bare-metal stents (BMS).12,13,14
Several trials comparing TiNOS with DES have been conducted but no systematic review of that evidence has been published so far.
Participants – Interventions - Outcome measures
The question was specified using the PICOS framework15: Patients presented CAD including ACS. Intervention was PCI using TiNOS. Comparator was PCI using DES. Outcomes were the device-oriented Major Adverse Cardiac Events (MACE) and the components of that composiste i.e., Cardiac death (CD), recurrent myocardial infarction (MI), and clinically driven target lesion revascularization (TLR). Probable or definite ST, and all-cause mortality (“total death”: TD) were also analyzed. Outcomes were assessed at 1-year and 5-year follow-ups. Study methods were prospective randomized controlled clinical trials (RCTs).
Methods
This systematic literature review (SLR) is the first to compare the efficacy and safety of TiNOS versus DES in CAD. It was designed and conducted according to methods described in the Cochrane Handbook with the use of “Grading of Recommendations Assessment, Development and Evaluation” (GRADE). The protocol was registered in PROSPERO (CRD4201809062) before initiation. It is reported according to “Preferred Reporting Items for Systematic Reviews and Meta-Analyses” (PRISMA).16-18
Data recording and the meta-analysis were conducted in RevMan 5.3 (Review Manager Version 5.3 software. Copenhagen, Denmark: The Nordic Cochrane Centre, 2014). The certainty of evidence according was rated with GRADEpro GDT software 2020 on-line version, (https://gradepro.org). Additional analyses were performed in STATA 16 (StataCorp LP, College Station, Tx, USA) using the metan and metaprop packages.
Data sources
MEDLINE, EMBASE, the Cochrane Library, and Web of Science (WoS) electronic databases, were queried on March 8, 2018, using their search engines. The search terms were: ((bioactive OR (Titanium AND nitride AND oxide) OR TiNO OR TNO OR BAS) AND stent) AND (DES OR (drug AND eluting AND stent)) AND (RCT OR ((randomized OR randomised) AND controlled AND trial)). No exclusion filter was applied related to language, country, year, or any other aspect. The websites of AHA, TCT, ESC, EuroPCR, and clinicaltrials.gov were also searched. The queries were updated on July 22, 2020, when all initially identified RCTs were published to retrieve new evidence if any, from RCTs meeting the PICOS specifications of this SLR.
The downloaded record files were imported and pooled and sifted in EndNote X8 (Clarivate Analytics, Philadelphia, PA, USA). One reference only was selected when duplicates were identified. When differerent references concerned the same study, their information was pooled using the citation of the most recent one. Full articles were reviewed for all references.
Study selection and Data extraction
Two reviewers (FD and LL) performed independently the following steps: (1)Exhaustive reference screening, (2)Reference classification according to the inclusion and exclusion criteria, (3)Extraction of study methods, (4)Patient baseline data, (5)Treatment data and results of each eligible RCT, (6)Individual eligible RCT risk of bias rating, (7)Assessment of the certainty of the evidence for each outcome variable according to GRADE. The results were recorded in RevMan 5.3 file.
Differences were adjudicated by a third reviewer (NM). The similarity of the definitions of endpoints across the RCTs was discussed with one investigator (PK). The risk of bias of individual RCTs was rated according to the criteria proposed by the Cochrane Collaboration with operator blinding as a separate item.
The screened studies were included if they met the following criteria: First-hand clinical evidence with prospective inclusion; patients with CAD treated with coronary PCI; implantation of either TiNOS or DES after the random allocation of the stent type; target outcomes reported at 1-year and/or 5-year follow-up; the outcomes reported as the number of patients who were included along with the number or proportion of them who presented an event of interest. Studies were ruled out if any of the study selection criteria were not met or if IRB/ethics committee approval and patient informed consent were not explicitly required.
The term ACS referred to patients who presented at baseline with ST-elevated myocardial infarction (STEMI), or non-ST-elevated myocardial infarction (NSTEMI), or unstable angina pectoris.
The definitions of outcomes aimed in this SLR protocol are those defined by the Academic Research Consortium (ARC).19 Data extraction is stratified according to patient clinical presentation, i.e., ACS versus with other CAD.
Statistical analysis
The two treatment arms are compared for each endpoint using the risk ratio (RR) defined as ((n patients with an event in TiNOS)/(n patients in TiNOS))/((n patients with an event in DES)/(n patients in DES)). As a result, RR > 1 reflects a higher frequency of events in the TiNOS arm than in the DES arm and conversely. Outcomes are analyzed on an intention-to-treat (ITT) basis. The numerator is the number of patients presenting an event and counted in the treatment arm they were randomized to and the denominator is the sample size of the corresponding arm.
For each endpoint, individual study RRs are calculated with their 95% confidence interval (CI [,]) and their degree of heterogeneity is determined. If no significant heterogeneity is detected, the pooled RR is calculated with its CI using the M-H method with a fixed-effect model.16,20,21 In the case of significant heterogeneity, pooling uses the M-H method with a random-effects model. The pooled analysis is stratified according to baseline clinical presentation, ACS versus other CAD. One-year and 5-year outcomes are analyzed separately. Sensitivity analysis is performed by iteratively recalculating the pooled RR after removing one eligible RCT. As a result, the impact of each RCT on the pooled RR is estimated. It estimates the impact of differences in stent generations and the potential risk of indirection related to differences in outcome definitions.
Patient and public involvement
No patient involved.
Results
Overall
Study identification, screening, and selection are described in the PRISMA flowchart (Figure 1). One hundred and eleven references were identified and nine publications with first-hand data about five RCTs are eligible for inclusion in the meta-analysis.
The number of patients with 1-year follow-up data is 1,855 in the TiNOS arm versus 1,363 in the DES arm. Those numbers are 783 versus 773 patients at 5-year follow-up. Three RCTs enrolled only patients presenting with ACS and two enrolled and analyzed jointly patients presenting with ACS and other CAD. TIDE enrolled 143 patients with ACS (47%) and TITANIC-XV, 112 (64.7%). The baseline characteristics are summarized in Table 1. Funnel plots and Harbord tests did not detect a risk of publication bias concerning any of the endpoints at 1-year follow-up in all CAD (supplemental material).
Four RCTs report or enable to deduct the number of cases of clinically driven TLR, CD, non-fatal recurrent MI, and the composite of CD or any non-fatal MI extended or clinically driven TLR. This results in a modified device-oriented MACE where MI “not clearly attributable to a nontarget vessel” is replaced by any MI. Given fatal MIs are counted as CD, this modification adds non-fatal MI in nontarget vessels.
In one RCT (TITANIC-XV), the primary endpoint is estimated from the available data as the sum of CD, any non-fatal MI, and any TLR assuming no overlap between those variables.
The risk of bias in individual RCTs is rated moderate or low except for the operator’s knowledge of the type of stent used during the intervention in all RCTs.
The pooled RRs of all outcomes at 1-year and 5-year follow-up are reported in Table 2 with CIs and sensitivity analyses. Results are reported overall and in the ACS subgroup. Given the 5-year follow-up of patients in the TIDES-ACS trial is ongoing, pooled RRs for 5-year outcomes are interim results.
The stratified (ACS relative to other CAD) pooled RRs of effectiveness endpoints show no significant difference in 1-year MACE and a significantly higher rate of TLR with TiNOS (Figure 2). The stratified stratified pooled RRs of safety endpoints show no significant difference in 1-year CD, but significantly lower rates in non-fatal, MI and ST with TiNOS compared to DES (Figure 3). The pooled RR of TD is also not significant (supplemental file).
The stratified pooled RRs analysis shows a much larger number of patients in the ACS subgroup compared to the other CAD subgroup (85.2% versus 14.8%). The overall effects are driven by the ACS subgroup. The results of the other CAD subgroup (TIDE and TITANIC-XV) are not interpretable because outcomes in patients with ACS are not reported separately. Therefore, the subsequent steps of this SLR are refocused on RCT about ACS only.
ACS at 1-year follow-up
The pooled RRs of effectiveness and safety endpoints in MACE are consistent with overall results but heterogeneity, robustness to sensitivity analysis (Table 2) and the level of certainty of the underlying evidence according to GRADE (supplemental material) need to be assessed separately.
The RR of MACE presents no significant heterogeneity, is robust to sensitivity analysis, and the certainty of evidence is rated high. The RR of clinically driven TLR presents no significant heterogeneity but results are not robust to sensitivity analysis, and the certainty of the evidence is rated low.
The pooled RRs of CD and TD present significant heterogeneity, are not robust to sensitivity analysis, and the certainty of the evidence is rated very low.
The pooled RR of non-fatal MI presents no significant heterogeneity, is robust to sensitivity analysis, and the certainty of the evidence is rated moderate.
The pooled RR of probable or definite SE presents no significant heterogeneity, is robust to sensitivity analysis, and the certainty of the evidence is rated low.
Discussion
TIDE and TITANIC-XV enrolled 255 patients with ACS but their data are not reported separately from the other patients. The impact of not including them in the ACS subgroup is limited given they represent 7.9% of all patients with ACS. The modified definition of device-oriented MACE results in including non-fatal MIs from nontarget vessels. One can reasonably assume the index stent does not affect those events. Ninety non-fatal MIs are reported. Assuming half of them are related to nontarget vessels (i.e., 45 cases), proportionality with sample size would lead to 27 fewer cases with TiNOS and 18 with DES, which would result in an RR of 0.19 [0.09, 0.42]. The inclusion of nontarget MIs thus results in a dilution that is favorable to DES. If the same numbers cases were removed from the count of MACE, the RR would be 0.98 [0.73, 1.30], which would not change the non-inferiority conclusion. The robustness to sensitivity analysis of the pooled RRs of MACE, MI, and ST in ACS, shows that the differences in DES generations, including the elution of paclitaxel and mTOR inhibitors do not significantly change those results. The interim 5-year pooled results will be updated when the final results of TIDES-ACS are published, but the current results are consistent with 1-year outcomes.
Conclusions
This systematic literature review shows that titanium-nitride oxide coated-coronary stents and drug-eluting stents have a similar risk of device-oriented major adverse cardiac events at one-year follow-up in patients with an acute coronary syndrome. This result is robust and the level of certainty of the evidence is high. It also shows a lower risk of recurrent myocardial infarction and stent thrombosis with titanium-nitride oxide coated-coronary stents than with drug-eluting stents with a potentially higher risk of target lesion revascularization. Interim five-year pooled outcomes are consistent with one-year outcomes. These results show that the titanium-nitride oxide coated-coronary stents are safe and effective in acute coronary syndrome at one-year follow-up.
Data Availability
This work used published summary data only.
Supplemental material
- Details of methods applied in this SLR.
- Methods of individual RCTs
- Table of the number of patients with events – ITT
- Funnel plots and results of Harbord tests.
- Summary of risk of bias in individual RCTs
- Pooled RR of CD or MI, and TD
- GRADE certainty of evidence assessment
- PRISMA checklist
Contributors
Frederic Daoud (FD): Main reviewer and meta-analyst with LL.
Louis Létinier (LL): Main reviewer and meta-analyst with with FD.
Nicholas Moore (NM): Third reviewer. Adjudicated disagreements.
Pierre Coste (PC): Advised on protocol and analysis.
Pasi Karjalainen (PK): Provided additional information about the methods of the individual trials.
Funding
This work was exclusively funded by the University of Bordeaux and INSERM BPH U1219, Bordeaux, France
Data sharing statement
All data included in this review are published.
Footnotes
1) Made additional formal changes to group effectiveness endpoints and safety endpoints in two sections, each with a compiled image file.